CAA-100A
Cable & Antenna Analyzer + Spectrum Analyzer
ShinewayTech® CAA-100A Cable & Antenna Analyzer with spectrum analyzer can test DTF / Frequency Return Loss, VSWR, Cable Loss, RF Power and Spectrum.
CAA-100A integrates two functions: cable and antenna measurements and spectrum analysis. Cable and antenna analyzer with frequency range 1MHz – 6GHz and 60dB dynamic range is suitable for 2G / 3G / 4G / 5G / WLAN / WiFi / WiMAX systems etc.
The spectrum analysis module supports frequency of 300MHz-4GHz and 100dB dynamic range. CAA-100A series is an essential measuring instrument for testing new generations of wireless network and indoor signal distribution.
Features
●Cable and Antenna analyzer, Spectrum Analyzer, Terminal RF Power Meter and RF In-Line Digital Power Meter Function
●Cable and Antenna analyzer function: Frequency range:1MHz to 6GHz, Dynamic Rang up to 60dB
●Spectrum Analyzer function: Frequency range:300MHz to 4GHz, Dynamic Rang up to 100dB
●Cable and Antenna analyzer function and Spectrum Analyzer function share port test
●Suitable for 2G / 3G / 4G / 5G / WLAN / WiFi / WiMAX system etc.
●Intelligent limit /marker /curve calculations
●More than 8 hours long battery life
●7 inch color LCD touch screen
●Optimized batch file management: edit/delete/filter
●Excellent Man-Machine interface for easy operation
1. Multiple Standard Measurement Mode
Spectrum, Power Meter, Distance-to-faultTo-Fault (DTF) Return Loss, DTF Voltage Standing Wave Ratio (VSWR), Frequency Return Loss, Frequency VSWR, Smith, Phase and Cable Loss testing. Main interface designs beautifully, user operation is convenient.
2. Optional Power Meter
USB high-precision power meter probe not only can connect the instrument to test and display the power, but also can connect the PC to analysisanalyze the result, which is greatly satisfyvery useful for user.
Terminating Power Meter and In Line Digital Power Meter can test a variety of signalsignals, which can meet the demand of different level users.
3. Intelligent Analysis and Judgment of the Trace
CAA-100A can analyze single or multi-segment limit lines, markers and the curve calculation accurately.
4. Convenient and Precise Calibrator:
(1) ECAL Electronic Calibrator (Standard)
(2) 1-Port “T-type” Calibration Kit (Optional)
It can calibrate precisely and conveniently. When the calibrated data points decrease, it is no need to recalibrate, which will increase the service efficiency.
Electronic calibrator ECAL provides consistent calibration results, and removes the possible error of manual calibration.
5. Instant Switching the Return Loss and VSWR
CAA-100A Cable & Antenna Analyzer’s function can test the return loss and VSWR simultaneously, and switch the result instantly.
6. Optimized Batch File Management Function
CAA-100A file filter function is easy to implement batch editing and analysisanalyzes the results.
7. Field Calibration Cable and Obtaining the Parameters
CAA-100A can supply user input the cable parameters (propagation velocity, cable loss) or choose a known cable type. If user knows nothing about the cable parameters, he can make a field calibration by the equipment cable Calibration tool to get the accurate cable parameters.
8. Manually Set Frequency or Select the Preset Frequency
According to the demand, it is convenient for user to manually set or select the preset frequency.
9. Smith Phase Testing
10. Energy Saving, Environmental Protection and Human Interface Design
CAA-100A is low-power designing, has a high-capacity rechargeable lithium battery and AC adapter dual power supply with more than 8 hours of continuous battery operation. The shortcut keys can set up four display modes: normal, black and white, highlight and night vision for different ambient.
11. Spectrum Analysis Module
The spectrum analysis module is covered 300MHz-4GHz, 100 dB dynamic range, -130dBm/Hz DNAL. It can supply the spectrum measurement, field strength analysis, interference and other testing.
(1) Spectrum Test Function
(2) Antenna Test Function
WCDMA
CDMA
13. CAA Workbench PC Software
(1) Data Management Function
●Uploading and downloading files between the CAA-100A host and PC
●Interact files with PC, including open the local file and save the file to the local
●Support report print preview and print. Fully display the information such as company name, test parameters and measuring time etc.
(2) Application Tools Function
●Distance-To-Fault
●Transform into Smith Chart
●Calculator
●Edit Signal Standard
●Edit Cable Parameter
(3) Data Analysis
●Marker
●Limit line
●Scale
●Switching the Return Loss and VSWR
Model
|
CAA-100A
|
Cable & Antenna Analyzer Function
|
Frequency Range
|
1-6000MHz
|
Frequency Resolution
|
1kHz
|
Frequency Accuracy
|
±2ppm
|
Output Power
|
0dBm (typ.)
|
Measurement Speed
|
1.5ms/pt
|
Data Points
|
137, 275, 551, 1103, 2207, 3310
|
Directivity
|
42dB (after calibration)
|
Anti-jamming Capability
|
17dBm@ Channel, -5dBm@ Frequency
|
Frequency
|
Return Loss Range
|
0-60dB
|
Return Loss Resolution
|
0.01dB
|
VSWR Range
|
1-65
|
VSWR Resolution
|
0.01
|
Cable Loss Range
|
0-30dB
|
Cable Loss Resolution
|
0.01dB
|
Distance-to-Fault
|
Distance-to-Fault Return loss Range
|
0-60dB
|
Distance-to-Fault VSWR Range
|
1-65dB
|
Measuring Range
|
1500 m
|
Resolution Ratio
|
1.5*10^8*Vp/(F2-F1)
Vp: the cable's relative propagation velocity; F1/F2: start/stop frequency
|
Spectrum Analyzer Function
|
Frequency
|
|
Frequency Range
|
300-4000MHz
|
Frequency Resolution
|
1kHz
|
Frequency Accuracy
|
±2.5ppm
|
Frequency Span
|
1-3700MHz
|
Resolution Bandwidth (RBW)
|
1k-300kHz(1,3,10 step)
|
Video Bandwidth (VBW)
|
1k-300kHz(1,3,10 step)
|
RBW/VBW
|
1,3,10
|
Amplitude
|
Attenuator Range
|
30dB
|
Attenuator Step
|
5dB
|
Max. Continuous Input
|
+26dBm
|
Third-Order Intercept
|
>+15dBm (typ.)
|
Second harmonic distortion
|
<-70dBc
|
Displayed Average Noise Level (DANL)
|
<-130dBm/Hz
|
Measurement Accuracy
|
±1.5dB@25±5℃ (typ.)
|
SSB Phase Noise @1GHz
|
-85dBc/Hz @ 10kHz offset; -120dBc/Hz @ 1MHz offset
|
Residual Spurious
|
<-85dBm
|
Display
|
Dynamic Range
|
<=100dB
|
Measurement Range
|
DANL to 20dBm
|
Reference Level Range
|
-80dBm - 30dBm
|
Amplitude Units
|
Logarithmically (dBm,dBv,dBmv,dBuv)
|
Detection
|
Sample, Peak, Negative, RMS, Standard
|
Triggers
|
Free Run, Video
|
VSWR
|
2.2:1(typ.)
|
General Information
|
Connector Type
|
N - Type female
|
Input Impedance
|
50 Ohm
|
Display
|
7 inch resistor touch screen, resolution 800×480
|
Data Interface
|
1PC USB Host Port, 1PC USB Device Port, 1PC 10M/100M Adaptive LAN Port
|
Memory Space
|
16G, >2000 traces
|
Language
|
Chinese, English, Spanish
|
Internal Battery
|
11.1V 7800 mAh Rechargeable Lithium Battery
|
External Adapter
|
110 - 240V, 50 - 60Hz, AC input; 16V, 3.75A, DC output
|
Operating Temp. Range
|
-10℃ - 50℃
|
Storage Temp. Range
|
-40℃ - 70℃
|
Humidity
|
0 - 85% (Non-Condensing)
|
Weight
|
2.5kg
|
Dimensions (L x W x H)
|
290×175×75 mm
|
TPM Module (Optional)-RF Terminal Power Meter
|
Frequency Range
|
50 - 4000MHz
|
Power Range
|
-40 - 20 dBm
|
Maximum Power
|
<23 dBm
|
Measure Uncertainty
|
≤±0.3db (15 - 35℃);≤±0.5dB( 0 - 50℃)
|
Input VSWR
|
<1.2
|
Burst Width
|
1µs - 60ms
|
Min Repetition Period
|
15Hz
|
Video Band
|
5MHz
|
Minimum Pulse Width
|
200ns
|
Time Resolution
|
0.1µs,1µs,15µs,150µs
|
Peak Average Ratio
|
<12dB
|
CCDF Range
|
0.1% - 100%
|
CCDF Uncertainty
|
±3%
|
Duty Cycle
|
0.1% - 100%
|
Power Supply
|
USB
|
Operating Temp. Range
|
0℃ - 50℃
|
Storage Temp. Range
|
-20℃ - 70℃
|
Humidity
|
0 - 85% (Non-Condensing)
|
Weight
|
0.3kg
|
Dimensions (L x W x H)
|
125×45×35mm
|
DPM Module (Optional)-RF In Line Digital Power Meter
|
Average Power Measurement
|
Frequency Range
|
300-4200MHz
|
Power Range
|
100mW-200W
|
Dynamic Range
|
≥33 dB
|
Insertion Loss
|
≤0.1 dB
|
VSWR
|
1.05 to 99.9
|
Directivity
|
≥30 (<3GHz); ≥28 (>3GHz)
|
Accuracy
|
±4% (0℃ - +15℃ or +35℃ - +50℃ increase 3%)
|
Impedance
|
50Ω
|
Connector
|
N (Female)
|
Data Interface
|
USB
|
Peak Power Measurement
|
Peak Power Range
|
100mW to 500W
|
Peak Power Accuracy
|
Burst width >200us: ±7%; 1us<Burst width< 200us: ±10%; 0.5us<Burst width< 1us: ±15%; Burst width< 0.5us: ±20%;
|
Peak Average Ratio
|
0 to12dB
|
CCDF
|
Measurement Range
|
0.1 to 100%
|
Measurement Accuracy
|
±3%
|
Threshold Measurement Range
|
0.05W to 500W
|
Burst Power
|
Burst Power Range
|
100mW to 200W
|
Burst Width
|
1us to 60ms
|
Min. Measurement Frequency
|
15Hz
|
Measurement Accuracy
|
±6%
|
Duty Cycle
|
0.0001 to 1
|
General Specifications
|
Power Supply
|
USB
|
Operating Temperature
|
-10℃ to 50℃
|
Storage Temperature
|
-20℃ to 70℃
|
Relative Humidity
|
0 to 85% (Non-condensing)
|
Weight
|
0.48kg
|
Dimensions (H×W×T)
|
130××124×34mm
|
* Specifications subject to change without notice.
Order Information
Standard Package:
Instrument, Lithium Battery, AC Adapter, CD(PC Software, User Manual), Carrying Case, ECAL-- Electronic Calibrator, Cable (1.5m DC to 6GHz, N(m)-N(f), 50Ω), Adapter (N(m)-N(m), DC to 6GHz, 50Ω)
Optional (Module, Test Cable, Adapter, Calibrator)
Modules:
● TPM Module (Optional)--RF Terminal Power Meter
● DPM Module(Optional)—RF In Line Digital Power Meter
Test Cables:
● 1.5m, N(m)-N(f), DC to 6GHz, 50 Ohm
● 1.5m, N(m)-N(m), DC to 6GHz, 50 Ohm
● 1.5m, N(m)-7/16 DIN(f), DC to 6GHz, 50 Ohm
● 1.5m, N(m)-7/16 DIN(m), DC to 6GHz, 50 Ohm
● 3m, N(m)-N(f), DC to 6GHz, 50 Ohm
● 3m, N(m)-N(m), DC to 6GHz, 50 Ohm
Adapters:
● SMA(m)-N(m), DC to 6GHz, 50 Ohm
● SMA(f)-N(m), DC to 6GHz, 50 Ohm
● SMA(m)-N(f), DC to 6GHz, 50 Ohm
● SMA(f)-N(f), DC to 6GHz, 50 Ohm
● BNC(f)-N(m), DC to 6GHz, 50 Ohm
● 7/16 DIN(f)-N(m), DC to 6GHz, 50 Ohm
● 7/16 DIN(f)-N(f), DC to 6GHz, 50 Ohm
● 7/16 DIN(m)-N(m), DC to 6GHz, 50 Ohm
● 7/16 DIN(m)-N(f), DC to 6GHz, 50 Ohm
● 7/16 DIN(m)-7/16DIN(m), DC to 6GHz, 50 Ohm
● 7/16 DIN(f)-7/16DIN(f), DC to 6GHz, 50 Ohm
● N(m)-N(m), DC to 6GHz, 50 Ohm
● N(f)-N(f), DC to 6GHz, 50 Ohm
● N(m) 50Ohm – N(f) 75Ohm,DC to 3GHz
● N(f) 50Ohm – N(m) 75Ohm,DC to 3GHz
Calibrators:
● T-type Calibration Kits
Antenna:
● 880 MHz -- 960 MHz, N(m), 13 dBi, Yagi
● 1710 MHz -- 1990 MHz, N(m), 13 dBi, Yagi
● 1920 MHz -- 2170 MHz, N(m), 13 dBi, Yagi
● 2400 MHz -- 2500 MHz, N(m), 13 dBi, Yagi
● 890MHz-960MHz,1710MHz--1990MHz,N(m), 3dBi, 50Ω, Rod
● 1920 MHz -- 2170 MHz, N(m), 50 Ω, 3dBi,Rod
● 2400 MHz -- 2483 MHz, N(m), 50 Ω, 5dBi, Rod
● 890MHz-960MHz,1710MHz-1990Mhz,50Ω,N(m), 3.5dBi,Sucker
● 890MHz-960MHz,1710MHz-1990Mhz,50Ω,N(m), 3dBi, Sucker
● 2400MHz-2483MHz, 50Ω,N(m), 7dBi, Sucker
● 890MHz-960MHz, 50Ω,N(m), 6dBi, FRP
● 2400MHz-2483MHz, 50Ω,N(m), 10dBi, FRP
● 700 MHz -2.5 GHz, 50Ω,N(m), 4dBi, Logarithm
● 700 MHz - 4 GHz, 50Ω,N(m), 4dBi, Logarithm